Accurate wafer temperature for GaN/Si power electronics

Laytec and partners develop solution based on UV pyrometer Pyro 400

Temperature measurements during MOCVD growth of GaN-on-silicon (GaN/Si) devices are challenging. Theoretically, conventional infra-red (IR) pyrometry should be sufficient because the silicon substrate is IR absorbing in the full range of relevant growth temperatures.

However, one artifact makes the feed-back control difficult and prohibits precise statistical process control in industrial applications. Fig. 1 shows this phenomenon: when GaN is grown, the temperature signal (red) starts oscillating by ±2 K.

Laytec with partners at Otto-von-Guericke University of Magdeburg (Armin Dadgar and his team) and Ferdinand-Braun-Institute (Frank Brunner) have been looking for a solution.

They found that, no matter how perfect the IR pyrometer is, these oscillations are inevitable. They are caused by a complex interaction between two effects: the IR transparent GaN/AlGaN strain-engineering layers together with the defect reducing buffer structure and on the other hand the thermal IR radiation out of the silicon wafer that passes through the grown structure.

The solution was to use a pyrometry wavelength range in which the complex buffer layer structure Si/Al- GaN/GaN/LT-AlGaN/GaN is not "˜visible' for the pyrometer. It used LayTec's UV pyrometer Pyro 400, which was developed some years ago for GaN-on-sapphire growth in LED industry.

The results are demonstrated in Fig. 2. The same wafer as in Fig. 1 was transferred to a reactor at FBH with two in-situ tools: Pyro 400 for UV pyrometry and EpiCurve TT for IR pyrometry (950nm emissivity corrected), reflectance as well as wafer bow measurements.

The UV pyrometer (Fig. 2 - blue) gives a very stable wafer temperature signal without oscillations during GaN growth. Measurements on a reference GaN/GaN wafer in the same run (not shown here) verified that both IR pyrometer and Pyro 400 are well calibrated and give exactly the same temperature on an ideally flat and smooth GaN/GaN wafer.

Fig. 2 shows UV pyrometry measurements clearly indicating that the true GaN surface temperature of the GaN/ Si template wafer is ~5K lower than that of the basically flat GaN/GaN wafer due to the ~100 km-1 convex bow of the Si template measured by EpiCurve TT.

Furthermore, it became clear: the remaining oscillations in the IR pyrometry signal (red) are not the most important artifact. Due to interactions of the thermal IR radiation with the internal structure of the GaN/Si buffer, there is an additional downshift in this temperature signal by about 15 (!) K. 

This effect is attributed to the fact that the thermal IR radiation coming out of the silicon suffers intensity losses while passing the highly defective region at the Si/GaN interface. These internal straylight losses depend on the Fabry-Perot resonance within the total GaN thickness and, therefore, also contribute to the IR temperature oscillations.

A scientific paper with a detailed root cause analysis is in the pipeline and will be published later this year. 

×
Search the news archive

To close this popup you can press escape or click the close icon.
×
  • 1st January 1970
  • 1st January 1970
  • 1st January 1970
  • 1st January 1970
  • View all news 22645 more articles
Logo
×
Register - Step 1

You may choose to subscribe to the Compound Semiconductor Magazine, the Compound Semiconductor Newsletter, or both. You may also request additional information if required, before submitting your application.


Please subscribe me to:

 

You chose the industry type of "Other"

Please enter the industry that you work in:
Please enter the industry that you work in: