Growth Rate and Emissivity-Corrected Pyrometry in MBE Systems

News

K-Space Associates releases new technical note on its Integrated Control for Epitaxy (kSA ICE) instrument

Metrology instruments manufacturer k-Space Associates has released a new technical note on continuous reflectivity measurements for growth rate and emissivity-corrected pyrometry (ECP) in MBE systems.

Real-time growth rate and wafer temperature measurement during MBE growth are important to the final product quality and yield.These measurements have been historically difficult to obtain. Taking the measurement is challenging because of variation in the reflectivity signals caused by substrate wobble. These variations are exacerbated by the relatively long substrate-to-detector distances in MBE systems (typically greater than 24inch) compared to MOCVD systems (typically less than 12 inch). This results in oscillations in both the measured reflectivity and the temperature.

The kSA Integrated Control for Epitaxy (kSA ICE) instrument provides reflectivity and ECP measurements that can be used during MBE growth. This results in real-time material deposition calibration and process control in both continuous and triggered modes. The optics have been configured to overcome the wobble and path length issues in MBE.


Figure: 532 and 940 nm reflectivity during growth of 250 nm of AlAs followed by 500 nm of GaAs on a GaAs substrate, and the corresponding virtual interface reflectivity fits for each layer and wavelength. (“Continuous Reflectivity Measurements for Growth Rate and Emissivity-Corrected Pyrometry in MBE Systems”, https://www.k-space.com/products/ksa-ice/)

The figure shows the simultaneous measurement of the surface reflectivity at 532 nm and 940 nm during growth of AlAs and GaAs films on a GaAs substrate. For a deposition with constant growth rate, the oscillation period is proportional to l/2n. As such, the oscillation period of the 532 nm reflectivity data is shorter than that of the 940 nm reflectivity data, as seen in the figure. A shorter oscillation period allows the fit to converge earlier in the growth. As a result, the shorter wavelength 532 nm reflectivity data allows the calculation of film thickness earlier in the growth and allows characteristically thinner layers to be measured (under 350 nm). Conversely, 940 nm reflectivity continues to produce strong oscillations beyond 350 nm.

Additional data is available in the full technical paper, “Continuous Reflectivity Measurements for Growth Rate and ECP in MBE Systems,” at https://www.k-space.com/products/ksa-ice/.

×
Search the news archive

To close this popup you can press escape or click the close icon.
Logo
x
Logo
×
Register - Step 1

You may choose to subscribe to the Compound Semiconductor Magazine, the Compound Semiconductor Newsletter, or both. You may also request additional information if required, before submitting your application.


Please subscribe me to:

 

You chose the industry type of "Other"

Please enter the industry that you work in:
Please enter the industry that you work in: